Adec & W&H Handpiece Repair Specialists
Why Adec Owners Trust Us
We've been repairing Adec and W&H handpieces for Colorado dental practices since 2019 — every job gets quality parts, a hands-on technician, and a comprehensive warranty behind the work.
- Adec and W&H serviced as one family, because they are
- Full 6-month parts and labor warranty
- Free prepaid shipping label with every repair
- Free diagnostic estimate before any work begins
Adec & W&H Repair Pricing
High-Speed Handpiece Rebuilds From $129
Synea 96, 97 and 98 turbine rebuild: bearings, chuck and O-rings replaced, then speed-tested — with tighter tolerances allowed on the small-head 97.
Low-Speed Attachments From $145
Contra angles and attachments stripped to the gear train and rebuilt, then run under load, plus a coupling check, because on an Adec chair the coupling is often the real fault.
Electric Handpieces From $229
WK-93, WG-99 and WA-99 LT electrics: gears, bearings and seals renewed, then torque verified, and the LED or light path tested on the optic models.
Common Adec & W&H Repair Issues We Fix
W&H builds a handpiece that will run for years and then punish neglect. Almost everything that reaches us on an Adec traces back to maintenance rather than a fault in the head: the wrong lubricant, no lubricant, or an autoclave cycle run dry. Looked after properly these are among the most reliable heads in any operatory, which is why a failing one is usually telling you something about the maintenance routine rather than the handpiece.

Coupling Leaks
Worn O-rings at the coupling bleed air and water before they cause an obvious failure. You lose cutting power gradually and the spray drifts off the bur, and because it happens over months most practices adapt to it rather than notice it. One of the cheapest repairs we do and one of the most commonly ignored.
Turbine Bearing Wear
Rising pitch, vibration through the grip, or a drop in RPM you can feel on the tooth. On the 96, 97 and 98 heads the bearings go first and are the cheapest thing to put right. Left alone the vibration destroys the chuck seat and turns a bearing job into a full rebuild.
LED Failure on the 98 LED
When the light goes on a 98 LED, the emitter or its driver is almost always the culprit rather than the handpiece body. That makes it a far smaller repair than most practices assume, and well worth diagnosing before you write the handpiece off.
Chuck Wear and Bur Slippage
A bur that creeps down or spins under load means the collet has worn past tolerance. Left in service it damages bur shanks and eventually the head itself. We replace the chuck assembly and pull-test the grip before it goes back in the box.
WA-99 LT Losing Power
The LT is an electric attachment, so lost power usually traces to worn gearing or bearings inside the head rather than the motor driving it. Those are different repairs with very different costs, which is why we diagnose which one it is before we quote you rather than after.
Water Spray Off Target
Corroded or blocked water ports throw the spray off the bur, and that means heat at the prep. We clear the ports, replace the O-rings and verify the spray pattern against the bur before the handpiece is packed.
How to Send Us Your Adec Handpiece
Five steps, and four of them are ours. The part you handle should take minutes.
- Ask for a label. Call (720) 998-2820 or use the estimate form. A prepaid USPS label reaches you the same business day, no minimum order, nothing to pay up front.
- Box it up. Bubble wrap, sturdy carton, and a note with your practice name and the symptom. On an Adec, send the coupling in the box — a good share of what gets reported as a handpiece fault turns out to be worn coupling O-rings.
- We look, then we quote. Inspection is free, and nothing is opened past that point until you have a written price and have approved it.
- We rebuild and prove it. Cleaned, rebuilt, then speed, torque and spray pattern checked on the bench, and the LED driver tested if it is a 98 LED.
- Back to your operatory. UPS or FedEx, roughly 7 business days from arrival, under the 6-month parts and labor warranty.
Adec & W&H Models We Service
Adec-branded handpieces are manufactured by W&H, which is why we service the two as a single family rather than treating them as separate brands. If you run an Adec operatory, these are the heads hanging on your delivery system, and downtime on one of them stops a chair. Below are the models we service most often — if yours is not listed, call us at (720) 998-2820.
We rebuild every major handpiece brand on the same terms and the same bench. If your operatory runs more than one, see our KaVo handpiece repair, Midwest handpiece repair, Star handpiece repair and NSK handpiece repair pages, or browse every brand we repair.
Adec & W&H High Speed Turbines
Adec / W&H 96, 97, 98 and 98 LED — the Synea turbine family. The numbers are largely a head-size distinction: the 98 is the standard head and the 97 is the small head, which matters at repair time because the tighter the space around the turbine cartridge, the less margin there is for debris or a bearing fitted even slightly out of tolerance. Every one of these gets the same rebuild — new bearings, new chuck, fresh O-rings, a full clean and a speed test before it ships back.
Adec & W&H Electric Attachments
Adec WK-93 and WG-99 — 1:5 speed increasing contra angles from the Synea Vision and Synea Fusion lines. As with the turbines, the model number tracks head size, and the smaller WK-93 head is the less forgiving of the two. We rebuild the gear train and bearings as a set and verify torque under load, because on a speed increaser torque fades before the speed does.
Adec / W&H WA-99 LT — the earlier-generation 1:5 lighted contra angle. These are still in daily use in a lot of operatories, and a power complaint on one usually traces to worn gearing or bearings rather than the motor driving it. We diagnose which before we quote you.
Couplings and Light Sources
A large share of what looks like a handpiece fault on an Adec chair is actually the connection. Worn coupling O-rings bleed air and water, which shows up as lost cutting power and a spray that will not sit on the bur — an inexpensive fix that is easy to keep ignoring while performance quietly drops. On the LED models the emitter and its driver fail far more often than the handpiece body does, which usually makes it a cheaper repair than practices expect. We test the coupling and the light path as part of every Adec job, not as an extra.
Frequently Asked Questions
Because Adec handpieces are built by W&H, the same questions come up whichever badge is on the barrel: whether we treat them as one family, what actually fails on the 96/97/98 heads, and whether an LED failure means a new handpiece. Below are the ones practices ask us most before sending an Adec unit in.
Are Adec and W&H handpieces the same thing?
Effectively, yes. Adec-branded handpieces are manufactured by W&H, so the internals, the tolerances and the service procedure are the same whichever name is printed on the barrel. That is why we quote and service them as one family rather than asking you to work out which brand you technically own. Every repair ships back with our full 6-month parts and labor warranty and a free diagnostic estimate up front, and we send you a free prepaid USPS shipping label to get it to our office with no minimum order value.
Do you repair the LED models, including the LED assembly?
Yes, including the LED assembly itself. This is worth knowing because a dead light on a 98 LED is usually the emitter or its driver rather than the handpiece, which makes it a much smaller repair than most practices assume. Send it in and we will tell you which it is before you commit to anything.
What is covered under the warranty?
Every Adec and W&H repair carries a full 6-month parts and labor warranty, and you get a free diagnostic estimate before any work begins — you will never receive an invoice you did not approve first. If a handpiece turns out not to be worth repairing, there is no repair charge at all: a flat $29 covers shipping and handling and it goes back to you.
What parts do you use on Adec repairs?
We use quality replacement parts matched to your specific model rather than close-enough substitutes, and we rebuild to specification so fit, torque, light output and spray pattern match how the handpiece left the factory. On the Synea heads that precision matters more than on most brands, because the small-head models leave very little margin around the turbine cartridge. If you want to know exactly what is going into your handpiece, call us at (720) 998-2820 and we will tell you before we order it.